Skip to content
Indianapolis CMM Calibration and Repair

Primary service

CMM Calibration and Repair


Request a quotation for calibration or repair.

Request a quotation

The quotation is put in writing and delivered by email.

Verification against a stated specification

Calibration establishes a machine's relationship to reference values with a stated uncertainty. What most inspection departments buy is performance verification: a pass/fail test against ISO 10360-2 or ASME B89.4.1, usually paired with geometric adjustment and, where the controller allows it, an update to the volumetric error compensation map.

Bridge, gantry, cantilever and horizontal-arm machines are tested under that pairing. Fourth-axis rotary tables are tested separately under ISO 10360-3:2000, using two test spheres at a specified height difference and radius. Articulated arms, laser trackers and multisensor systems each carry their own governing standard, applied where applicable to the configuration on hand.

What a visit covers

Each calibration visit follows a fixed sequence, starting with the scales and ending with a certificate.

  • 01

    Scale and reader head

    X, Y and Z scales are cleaned and inspected; reader head output is checked against specification.

  • 02

    Air bearings and lines

    Bearing clearance and airline condition are checked before any geometry test is run.

  • 03

    Geometry

    Straightness, linearity and squareness are tested in the XY, ZX and ZY planes.

  • 04

    Length and probing error

    E0 and E150 are tested per ISO 10360-2, with PFTU probing error tested on a separate calibrated test sphere per ISO 10360-5.

  • 05

    As-left verification

    Results are re-run after any adjustment and recorded alongside the as-found data.

Sequence on site

  • 01

    Inspect

    Scales, reader heads, bearings and lines are checked before any test runs.

  • 02

    Test as-found

    Geometry, length and probing error are measured and recorded before adjustment.

  • 03

    Adjust

    Geometric correction and compensation-map updates are applied where the controller allows it.

  • 04

    Verify as-left

    Tests are repeated and the certificate is issued against the governing standard.

Why Indianapolis CMM Calibration and Repair

  • 01

    As-found recorded first

    Adjustment never precedes the recorded as-found result, by sequence.

  • 02

    Repair scoped separately

    Probe, scale, bearing and drive repair is quoted apart from routine verification.

  • 03

    Error-map access checked

    OEM-locked compensation maps are identified before a visit is scheduled.

Coverage across Indiana and the Greater Midwest

On-site scheduling and travel terms vary by distance from Indianapolis; confirm coverage for a specific address before booking.

Discuss CMM Calibration and Repair Requirements

Submit machine make, model and travel range for a quotation.

The quotation is put in writing and delivered by email.